Edward, that target (IT874R 3x) was designed for the iSis and DTP70. To measure it on an i1iO in i1Profiler, you will have to go into patch mode, which is very slow but should work if you are desperate.
There is no i1iO reference file for that target but I am attaching the original IT874R 3x iSis.txt file which gives you CMYK percentages. Also to be safe, I'm attaching the visual version, IT874V 3x iSis.txt.
In i1Profiler, use the "Measure Chart" option and set up a custom layout of 49 x 33, then join the measurements to the CMYK values in Excel.
You may have to switch to 33 x 49 and experiment a bit to get the right patch values.
Good luck!
------------------------------
Don Hutcheson
HutchColor, LLC
Washington NJ
908-500-0341
don@...------------------------------